5-179
Chapter 5: Web Based Management Utility
Interface Configuration
Clicking the INTERFACE CONFIGURATION tab brings up the IGMP INTERFACE
C
ONFIGURATION page (Figure 5-153). The parameters for this page are shown in
Table 5-130.
Figure 5-153. IGMP Interface Configuration Page
Table 5-130. IGMP Interface Configuration Page Parameters
Parameter Description
Interface This parameter specifies the interface index.
IGMP Status This parameter specifies the IGMP Status.
Operating Version
With this parameter you can choose to run either in IGMP Version 1, IGMP
Version 2 or IGMP Version 3. This can be configured for every interface.
Fast Leave
This parameter indicates whether the fast leave processing for a specific
interface, is to be enabled or disabled.
Query Interval
This parameter indicates the interval between two successive IGMP queries.
The value ranges between 1 and 65535. The default value is 125.
Query Response
Time
This parameter specifies the response time for IGMP queries. The value ranges
between 1 and 255. The default value is 100.
Robustness Value
This parameter specifies the R
OBUSTNESS VALUE on this interface. The value
ranges between 1 and 255. The default value is 2.
Last Memb Query Int
This parameter specifies the IGMP last member query interval for the interface.
The value ranges from 1 to 255. The default value is 10.