PERIODIC MAINTENANCE 2-3
MAINTENANCE AND TUNE-UP PROCEDURES
This section describes the servicing procedures for each item
mentioned in the Periodic Maintenance chart.
AIR CLEANER
If the air cleaner is clogged with dust, intake resistance will be
increased, with a resultant decrease in power output and an
increase in fuel consumption. Check and clean the air cleaner
element in the following manner.
Remove the air cleaner case cover
1.
NOTE:
Be careful not to drop the O-ring into the air cleaner box that is
attached to the air cleaner case cover.
Loosen screw
2 to remove the air cleaner element
3.
Separate the polyurethane foam element
4, element frame
5 and element holder
6.
Fill a wash pan of a proper size with a non-flammable clean-
ing solvent. Immerse the air cleaner element in the cleaning
solvent and wash it.
Press the air cleaner element between the palms of both
hands to remove the excess solvent: do not twist or wring the
element or it will tear.
Immerse the element in motor oil, and then squeeze out the
excess oil leaving the element slightly wet.
A Non-flammable cleaning solvent
B Motor oil SAE #30 or SAE 10W-40
Clean every 1 000 km (600 miles, 3 months).