8-16 ELECTRICAL SYSTEM
Measure the relay coil resistance between the terminals using
the multi circuit tester. If the resistance is not within the specified
value, replace the starter relay with a new one.
# 09900-25008: Multi circuit tester set
) Tester knob indication: Resistance (Ω
ΩΩ
Ω)
& Starter relay resistance
Standard: 3 – 5 Ω
ΩΩ
Ω
NEUTRAL RELAY INSPECTION
• Remove the seat. (! 7-4)
• Disconnect the neutral relay.
Apply 12 V to terminals
1 and
2 (
+ to
1 and
- to
2) and
check the continuity between
3 and
4 using a multi circuit
tester. If there is no continuity found, replace the neutral relay
with a new one.
# 09900-25008: Multi circuit tester set
, Tester knob indication: Continuity set (-)
PARKING BRAKE SWITCH
(!8-33)