F67 – Manual Leap Seconds Entry/Request
F67 <SP>NONE<CR>
where:
NONE = ASCII string indicating a manual leap second insertion function will be disabled.
The Serial/Network port will respond with the message “ERROR 01 VALUE OUT OF
RANGE” if the input string was in the correct format but contained a value, probably
numeric, that was out of the range of acceptable values.
The Serial/Network port will respond with the message “ERROR 02 SYNTAX” if it
receives a string in an incorrect format, for example the second field should be S, LS,
ADD, SUB or NONE.
The Serial/Network port will respond with the message “ERROR 03 BAD/MISSING
FIELD” if the input string lacks a required field.