EasyManuals Logo

SYNAPTICON SOMANET Node 400 User Manual

Default Icon
887 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #859 background imageLoading...
Page #859 background image
KYT 84-130: 5 Ω per °C
Note
Some analog inputs have a low input resistance. The internal input resistance is connected in parallel to
the input.
Example: Measuring a motor temperature using a PT1000 temperature sensor
According to the PT1000 resistance table (provided, for example, from your sensor’s datasheet) the
resistance of the sensor should be 1000 Ω for 0° C and 1385 Ω for 100° C.
The reference voltage is 5 V, and the ADC resolution is 12 bits, so the ADC output value would be 4095
for full scale input voltage.
The image below depicts a schematic of input circuits. The ADC will measure the input voltage which is
proportional to the resistance.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 859/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node 400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node 400 and is the answer not in the manual?

SYNAPTICON SOMANET Node 400 Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node 400
CategoryServo Drives
LanguageEnglish

Related product manuals