Section IV – Diagrams
MN06135 Issue/Rev. 1.3 (6/17) 22
Figure 10. Wiring Diagram, Prime 4 Meter Single Pulse
Note: Wiring between transmitter and AccuLoad should be done with a shielded cable per each transmitter. If selected cable utilizes
twisted pairs, do not run more than one signal in a twisted pair.
Caution: For clarity, shields not shown. Connect shields to terminals 3, 13, 14, or 15 of Terminal Block 4.
Prime 4 Wire Codes:
Black: Common
Red: Input Power
White: Signal A Output
Yellow: Signal B Output