6. COORDINATE MEASUREMENT
6-11
*6) Error message will be displayed when the angle of dHD or dZ is exceeded 999mm, and the
display changes to select for remeasurement. Press [F3](YES) key to select remeasurement and
start from the procedure
.
Horizontal distance discrepancy (dHD)
dHD = [Horizontal distance between known point A and B based on
measured value] [Horizontal distance between known point A and
B based on inputted coordinate value of known point A and B]
Z coordinate discrepancy (dZ)
dZ = [Z coordinate value of the instrument calculated from measured value
of known point A] [Z coordinate value of the instrument calculated
from measured value of known point B]
In selecting 2 Dimensional measurement, Z coordinate discrepancy (dZ) will not be
displayed.
*7) The screen displays selecting for remeasurement when [F4](NO) keys is pressed. Press
[F3](YES) key to start remeasurement and returns to the procedure
.
*8) In selecting 2 Dimensional measurement, N and E coordinate only will be set newly.
* Press [ESC] key or [F1](EXIT) key to cancel the setting mode on the way.