Configuration
Topcon HiPer Lite and HiPer Lite+ Operator’s Manual
2-6
3. Select the Power Mode drop-down list to set the desired
power source (Figure 2-3). Current Mode displays the
current power source.
• Auto – receiver automatically selects the power source
• Mix – receiver automatically detects and consumes
power from the source with the largest voltage
• Battery A – receiver consumes power from battery A
• Battery B – receiver consumes power from battery B
• External – receiver uses an external power supply
Figure 2-3. Select Power Mode
4. Select the Charger Mode drop-down list to set the desired
charger mode (Figure 2-4 on page 2-7). Current Mode
displays the charging battery: a, b, or none (off).
• Off – receiver will not charge batteries
• Charge A – receiver charges only battery A
• Charge B – receiver charges only battery B
• Auto – receiver automatically detects and charges both
batteries