Step2:Removethemotor/generatorassemblyfromthemachine.
g035728
Figure126
1.Operator’sseat3.Motor/generatorcontroller(mountedtomotor/generator
assembly)
2.Motor/generatorconnectorP37
Removethemotor/generatorassemblyfromthemachine.RefertoChapter5ofthe5010-HServiceManual.
SeeFigure126.
Step3:Removethecontrollerfromthemotor/generator.
Removethecontrollerfromthemotor/generator.RefertoChapter5ofthe5010-HServiceManual.
Step4:Inspectthewiringbetweenthemotor/generatorandthe
controller.
Themotor/generatorandthecontrollereachhavecablingthatconnectstotheothercomponent.Inspectthe
wiringbetweenthecontrollerandthemotor/generator.
Pass
Thewiringbetweenthecontrollerandthemotor/generatorpassedinspection.GotoStep5.
Fail
Thewiringbetweenthecontrollerandthemotor/generatordidnotpassinspection.Onlyrepair
wiringthathasworninsulationorarecessedconnectorpin.Replaceallcomponentsthathave
damaged,burned,orbrokenwiring.GotoReturningtheMachinetoService(page22)andfollow
thestepslisted.
Step5:Installareplacementcontrollerontothemotor/generator.
RefertoChapter5ofthe5010-HServiceManualandfollowthestepslisted.
Step6:Installthemotor/generatorassembly.
RefertoChapter5ofthe5010-HServiceManualandfollowthestepslisted.
220