Step6:Testthepowerandgroundwiringinmainharnessconnectors
P48andP49.
1.ThesearediagnosticstepstohelpisolateproblemsidentiedinStep5.Useamultimetertotestthe
resistancebetweenthefollowingpairsoflocations:
LocationHarness
Connector
Pin
Wire
Color
Expected
Reading
ConnectorGraphic
1MainP491Red
2MainP373Red
Lessthan
2ohms
1MainP492
Black
(48V
Ground)
2MainP374
Black
(48V
Ground)
Lessthan
2ohms
1MainP481White
2MainP492
Black
(48V
Ground)
24kto26k
ohms
2.Ifoneormoreofthepowerandgroundwiringtestsfailed,repairorreplaceanywornordamagedparts.
GotoReturningtheMachinetoService(page22)andfollowthestepslisted.
ComponentLocationandElectricalConnections
Cuttingreelmotor4islocatedinthefront,leftposition.Thereare2electricalconnectionstothecuttingreel
motor:P48(4wire)andP49(2wire).