Pass
Themainharnessintegritychecksweregood.AttachconnectorP37tothemotor/generator.Go
toStep3.
Fail
Themainharnessconnectorinspectionfailed.Repairorreplacethewornordamagedparts.Goto
ReturningtheMachinetoService(page22)andfollowthestepslisted.
Step3:Removethemotor/generatorassemblyfromthemachine.
g035728
Figure166
1.Operator’sseat3.Motor/generatorcontroller(mountedtomotor/generator
assembly)
2.Motor/generatorconnectorP37
Removethemotor/generatorassemblyfromthemachine.RefertoChapter5ofthe5010-HServiceManual.
SeeFigure166.
Step4:Removethecontrollerfromthemotor/generator.
Removethecontrollerfromthemotor/generator.RefertoChapter5ofthe5010-HServiceManual.
Step5:Inspectthewiringbetweenthemotor/generatorandthe
controller.
Themotor/generatorandthecontrollereachhavecablingthatconnectstotheothercomponent.Inspectthe
wiringbetweenthecontrollerandthemotor/generator.
Pass
Thewiringbetweenthecontrollerandthemotor/generatorpassedinspection.GotoStep6
Fail
Thewiringbetweenthecontrollerandthemotor/generatordidnotpassinspection.Onlyrepair
wiringthathasworninsulationorarecessedconnectorpin.Replaceallcomponentsthathave
damaged,burned,orbrokenwiring.GotoReturningtheMachinetoService(page22)andfollow
thestepslisted.
428