4-29 4. [Basic operation] Operation methods of motor
3
4
9
7 Switch to [Setting mode].
Select "4. Basic parameter" and press the [OK]
key. The basic parameter screen is displayed.
8 Select <CMOd: Run command select> and press
the [OK] key.
You can also select <CMOd: Run command
select> on the [Easy mode] screen.
The setting screen is displayed.
9 Select "0: Terminal" and press the [OK] key.
The basic parameter screen is displayed.
Check that the setting value of <CMOd: Run
command select> is "0."
10 Select <FMOd: Frequency command select 1> and
press the [OK] key.
The setting screen is displayed.
1.History function
2.Direct access
3.Guidance function
4.Basic parameters
5.Extended parameters(F - - -)
Top
0.0HzSTOP
15:13
Monitor
Setting Mode
0.0HzSTOP
15:51
Basic parameters
CMOd : Run command select
FMOd : Frequency command select 1
vb : Manual torque boost 1
vL : Base frequency 1
1
10
4.80%
60.0Hz
Pt : V/f Pattern 0
2: Embedded Ethernet
3: RS485 com (connector 1)
4: RS485 com (connector 2)
5: Communication option
0.0HzSTOP
15:51
CMOd :Run command select
1: Operation panel,Ext panel
1: Operation panel,Ext panel
2: Embedded Ethernet
3: RS485 com (connector 1)
4: RS485 com (connector 2)
0.0HzSTOP
15:51
CMOd :Run command select
0: Terminal
F R
0.0HzSTOP
15:52
Basic parameters
CMOd : Run command select
FMOd : Frequency command select 1
vb : Manual torque boost 1
vL : Base frequency 1
0
10
4.80%
60.0Hz
Pt : V/f Pattern 0
F R

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m