E6582062
5-49 5. [Fundamental operation] How to use parameters
3
4
5
9
5. 3. 6 Increasing starting torque
<vb: Manual torque boost 1>
Function
The starting torque is increased by increasing the setting value when starting torque is required. It is
valid when the setting value of <Pt: V/f Pattern> is "0: V/f constant", "1: Variable torque", or "7: V/f 5-
point setting".
Parameter setting
Reference of setting
100% is based on 200V, or 400V.
Set the value within +2% of the default setting, generally.
Title Parameter name Adjustment range Unit Default setting
vb Manual torque boost 1 0.00 - 30.00 %
*1
*1 Depending on the capacity. Refer to [11. 6].
Important
The optimum value is programmed for each inverter capacity by default setting. When a value
larger than the reference value is set, an overcurrent trip may occur at startup.
Repeated operation with excessive torque boost may cause failure of IGBT in the power circuit.
When larger stating torque is required, consider using vector control.
For details, refer to [5. 3. 4].
0.0HzSTOP
15:25
Min: 0.00 Max: 30.00
X1000 X100 X10 X1
%
vb :Manual torque boost 1
4.80
Basic parameter
00
Output frequency (Hz)
Output voltage (V)
<vLv: Base frequency voltage 1>
<vL: Base frequency 1>
<vb> (%)

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals