E6582062
6. [Advanced] How to use parameters 6-12
4
4
6
9
6. 3. 1 Always enabling the input terminal functions
(always ON)
<F110: Always active function 1>
<F127: Always active function 2>
<F128: Always active function 3>
Function
These parameters select an input terminal function to be always enabled (always ON). You can set
three points.
Parameter setting
6. 3 Selecting terminal functions
Title Parameter name Adjustment range Default setting
F110 Always active function 1
0-177
*1
*1 For details on the input terminal functions, refer to [7. 2. 1].
6
F127 Always active function 2 0
F128 Always active function 3 0
6: Standby
7: 6(Invers)
8: Reset 1
9: 8(Invers)
10: Preset speed switching 1
0.0HzSTOP
12:47
F110 : Always active function 1

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals