E6582062
11. Table of parameters 11-68
1
9
11
11. 10 Setup menu
Parameter title Function
Mainly North
America
Mainly
Asia
Mainly
Europe
China Japan
FH
Maximum frequency
(Hz)
80.0 80.0 80.0 50.0 80.0
F307
Supply voltage
compensation
22223
F319
Regenerative over-flux
upper limit (%)
120 120 120 140 140
F417
Motor rated speed
(min
-1
)
*1
*1 Depending on the region and the capacity. Refer to [11. 6].
*1 *1 *1 *1
vLv, F171, F175,
F179
Base frequency
Voltage (V)
230 230 230 200 200
460 400 400 380 400
vL, UL, F170,
F174, F178, F204, F213,
F219, F225, F231, F237,
F330, F335, F364, F367,
F370, F426, F428, F814,
A316, A319, A322, A346,
A349, A352, A376, A379,
A382
Frequency (Hz) 60.0 50.0 50.0 50.0 60.0
F606, F643
Frequency (max of set
value) (Hz)
60.0 50.0 50.0 50.0 60.0
F405
Motor rated
Capacity (kW)
3.7 4.0 4.0 4.0 3.7 3.7
0.4 0.4 0.4 0.4 0.37 0.4

Table of Contents