E6582062
2. Installation and wiring 2-2
2
9
Take special care with the installation environment of the inverter. Install the inverter in a location that
secures space for ventilation and heat emitting (in the cabinet, etc.), considering heat generation and
occurrence of noise.
2. 1. 1 Installation environment
This inverter is an electronic control instrument. Take full consideration to install it in the proper operating
environment as follows.
(1) Do not install in any location of high tempera-
ture, high humidity, moisture condensation
and freezing and avoid locations where there
is exposure to water and/or where there may
be large amounts of dust, metallic fragments
and oil mist.
2. 1 Installation
WARNING
Prohibited
Do not place any inflammable object near the inverter.
If flame is emitted due to failure in the inverter, this will lead to fire.
Do not install the inverter in any location where the inverter could come into contact with water
or other fluids.
This will result in electric shock or fire.
Mandatory
action
Operate under the environmental conditions prescribed in the instruction manual.
Operations under any other conditions will result in failure.
CAUTION
Prohibited
Do not install the inverter in any place with large vibration.
The unit will fall due to the vibration, resulting in injury.

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m