E6582062
6-7 6. [Advanced] How to use parameters
3
4
6
9
Various signals are input to the inverter for motor operation.
For details on the input terminal function, refer to [7. 2. 1].
6. 2. 1 Selecting operation at simultaneous input of Fwd/
Rev commands
<F105: Fwd/Rev priority of both close>
Function
This parameter selects operation performed (reverse run or deceleration stop) when the Fwd and
Rev signals are simultaneously input.
Parameter setting
Difference between the settings
0: Reverse
When the Fwd and Rev signals are simultaneously input, reverse run is performed.
6. 2 Input signals to the control terminals
Title Parameter name Adjustment range Default setting
F105 Fwd/Rev priority of both
close
0: Reverse
1: Stop
1
0: Reverse
1: Stop
0.0HzSTOP
12:45
F105 : Fwd/Rev priority
Frequency command value
Frequency command value
ON
OFF
ON
OFF
Output frequency (Hz)
Time (s)
Terminal [F]
(Fwd run)
Fwd
Rev
Terminal [R]
(Rev run)
0

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m

Related product manuals