E6582062ï‚‚
6-7 6. [Advanced] How to use parameters
3
4
6
9
Various signals are input to the inverter for motor operation.
For details on the input terminal function, refer to [7. 2. 1].
6. 2. 1 Selecting operation at simultaneous input of Fwd/
Rev commands
<F105: Fwd/Rev priority of both close>
â– Function
This parameter selects operation performed (reverse run or deceleration stop) when the Fwd and
Rev signals are simultaneously input.
â– Parameter setting
â– Difference between the settings
0: Reverse
When the Fwd and Rev signals are simultaneously input, reverse run is performed.
6. 2 Input signals to the control terminals
Title Parameter name Adjustment range Default setting
F105 Fwd/Rev priority of both
close
0: Reverse
1: Stop
1
0: Reverse
1: Stop
0.0HzSTOP
12:45
F105 : Fwd/Rev priority
Frequency command value
Frequency command value
ON
OFF
ON
OFF
Output frequency (Hz)
Time (s)
Terminal [F]
(Fwd run)
Fwd
Rev
Terminal [R]
(Rev run)
0