E6582062
5. [Fundamental operation] How to use parameters 5-76
4
5
9
Important
This parameter is a function to display the output frequency of the inverter multiplied by the
factor. It does not display the actual motor speed or line speed precisely.
800
80 (Hz)
Output frequency (Hz)
0
0
800
Panel display
Panel display
80 (Hz)
Output frequency (Hz)
0
0
1000
200
80 (Hz)
Output frequency (Hz)
0
0
Panel display
Positive inclination
Negative inclination
Positive inclination with bias
<F702>
<F702>
<F702>
<F705>="1 ", <F706>="0.00"
<F705>="0", <F706>="80.00"
<F705>="1", <F706>="20.00"

Table of Contents

Other manuals for Toshiba TOSVERT VF-AS3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-AS3 and is the answer not in the manual?

Toshiba TOSVERT VF-AS3 Specifications

General IconGeneral
ModelTOSVERT VF-AS3
CategoryInverter
Overload Capacity150% for 60 seconds
Cooling MethodForced Air Cooling
Control MethodV/f control, Sensorless vector control
Braking UnitBuilt-in
Communication ProtocolsModbus RTU, DeviceNet, Profibus DP
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault
EnclosureIP20
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m