E6581158
F-22
6
<<Sample sequence diagram 2: Adjustment with pulse signals>>
RUN command (such as F)
Increasing (UP) signal
Decrementing (DOWN) signal
Set frequency clearing signal
Upper limit frequency
Command frequency (Hz)
(The dotted lines represent
effective output frequencies.)
Q If two signals are impressed simultaneously
If a clear single and an up or down signal are impressed simultaneously, priority will be given to the
clear signal.
If up and down signals are impressed simultaneously, The frequency will change at the specified up
or down rate.
Q About the setting of the initial up/down frequency
To adjust the frequency starting at a specified frequency other than 0.0 Hz (default initial frequency)
after turning on the inverter, specify the desired frequency using H (initial up/down frequency).
Q About the change of the initial up/down frequency
To make the inverter automatically save the frequency immediately before it is turned off and start
operation at that frequency next time power is turned on, set H (change of initial up/down
frequency) to 1 (which changes the setting of H when power is turned off).
Keep in mind that the setting of H is changed each time power is turned off.
Q Frequency adjustment range
The frequency can be set from 0.0Hz to HJ (Maximum frequency). The lower-limit frequency will be
set as soon as the set frequency clearing function (function number 43, 44) is entered from the input
terminal.

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)