E6581158
F-74
6
6.21 Operation panel parameter
6.21.1 Prohibition of key operations and parameter settings
H : Prohibition of change of parameter setting
H
: Prohibition of panel operation (FC)
H
: Prohibition of panel operation (RUN/STOP keys)
H
: Prohibition of panel emergency stop operation
H
: Prohibition of panel reset operation
H
: Prohibition of change of EOQF/HOQF during operation
Function
These parameters allow you to prohibit the operation of the RUN and STOP keys on the operation
panel and the change of parameters. Using these parameters, you can also prohibit various key
operations.
[Parameter setting]
Title Function Adjustment range Default setting
H
Prohibition of change of parameter
setting
0: Permitted, 1: Prohibited
0
H
Panel operation prohibition (FC)
0: Permitted, 1: Prohibited
0
H
Prohibition of panel operation
(RUN/STOP keys)
0: Permitted, 1: Prohibited
0
H
Prohibition of panel emergency stop
operation
0: Permitted, 1: Prohibited
0
H Prohibition of panel reset operation
0: Permitted, 1: Prohibited
0
H
Prohibition of change of
EOQF/HOQF during operation
0: Permitted, 1: Prohibited
1
Q Resetting method
Only the H parameter is designed so that its setting can be modified even if 1 (prohibited) is selected.

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)

Related product manuals