E6581158
F-44
6
6.13.7 Canceling the operation command
H : Reverse-run prohibition
Function
This function prevents the motor from running in the forward or reverse direction when it receives the
wrong operation signal.
[Parameter setting]
Title Function Adjustment range Default setting
H
Reverse-run prohibition
0: Forward/reverse run permitted
1: Reverse run prohibited
2: Forward run prohibited
0
6.14 Drooping control
Hҏ : Drooping gain
Hҏ
: Drooping insensitive torque band
Function
These parameters are used to allow the motor to “slip” according to the load torque current. Using
these parameters, the dead zone torque and the gain can be adjusted.
[Parameter setting]
Title Function Adjustment range Default setting
H
Drooping gain 0-100% 0%
H Drooping insensitive torque band 0-100% 10%
Drooping gain
Insensitive torque current
Torque current