EasyManua.ls Logo

Toshiba TOSVERT VF-S11 - 6.6 Operation frequency

Toshiba TOSVERT VF-S11
269 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E6581158
F-23
6
Q Minimum unit of frequency adjustment
If H (Frequency free unit magnification) is set to 1.00, the output frequency can be adjusted in
steps of 0.11Hz.
6.6 Operation frequency
6.6.1 Starting frequency
H : Starting frequency setting
Function
The frequency set with H is put out as soon as operation is started.
Use the H parameter when a delay in response of starting torque according to the
acceleration/deceleration time is probably affecting operation. Setting the starting frequency to a
value from 0.5 to 3Hz is recommended. The occurrence of an overcurrent can be suppressed by
setting this frequency below the rated slippage of the motor.
[Parameter setting]
Title Function Adjustment range Default setting
H
Starting frequency setting 0.5-10.0 (Hz) 0.5
Starting frequency settingH
Output frequency [Hz]
Time [s]
0

Table of Contents