Save user-defined parameters (V[R = )
Setting V[R to saves the current settings of all parameters.
Call user-defined parameters (V[R = )
Setting V[R to resets parameter settings to (calls up) those saved by setting V[R to .
, By setting V[R to or , you can use parameters as your own default parameters.
Cumulative fan operation time record clear (V[R = )
Setting V[R to resets the cumulative operation time to the initial value (zero).
Set this parameter when replacing the cooling fan, and so on.
5.7 Forward/reverse run selection (Operation panel op-
eration)
HT : Forward/reverse run selection (Operation panel operation)
• Function
Program the direction of rotation of the motor when the running and stopping are made using the RUN
key and STOP key on the operation panel.
Valid when EOQF (command mode) is set to (operation panel).
Q Parameter setting
Title Function Adjustment range Default setting
HT
Forward/reverse run selection (Opera-
tion panel operation)
0: Forward run
1: Reverse run
2: Forward run (F/R switching
possible)
3: Reverse run (F/R switching
possible)
0
+ When HT is set to or and an operating status is displayed, pressing the key with the key
held down changes the direction of rotation from reverse to forward after displaying the message
“HTH” Pressing the key again with the key held down changes the direction of rotation from
forward to reverse after displaying the message “HTT”
+ Check the direction of rotation on the status monitor. For monitoring, see8.1
HTH: Forward run
HTT: Reverse run
+ When the F and R terminals are used for switching between forward and reverse rotation from the ter-
minal board, the HT forward/reverse run selection parameter is rendered invalid.
Short across the F-CC terminals: forward rotation
Short across the R-CC terminals: reverse rotation.