E6581158
F-7
6
6.3 Terminal function selection
6.3.1 Keeping an input terminal function always active (ON)
H : Always-active function selection
Function
This parameter specifies an input terminal function that is always to be kept active (ON). (Only one
function selectable)
Q Parameter setting
Title Function Adjustment range Default setting
H
Always-active function selection 0-64 (See section 11, K-15) 1 (Standby)
6.3.2 Modifying input terminal functions
H
: Input terminal selection 1 (F)
H
: Input terminal selection 2 (R)
H
: Input terminal selection 3 (RES)
H
: Input terminal selection 4 (S1)
H
: Input terminal selection 5 (S2)
H
: Input terminal selection 6 (S3)
H
: Input terminal selection 7 (VIB)
H
: Input terminal selection 8 (VIA)

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)