Page #17 background imageLoading...
Page #17 background image
E6581158
A-5
1
The front panel is unlocked when
the dot on the locking screw is on
this (upper) side.
The front panel is locked when the
dot on the locking screw is on this
(lower) side.
Charge lamp
Front panel
Indicates that high voltage is still
present within the inverter. Do not
open the terminal board cover
while this is lit.
The front panel of the inverter or
terminal board
To avoid touching the terminal
board by mistake, be sure to close
the front panel before starting
operation.
Front panel locking screw
The inverter came with this
screw in the locked position.
So from this position, turn the
screw 9 counterclockwise to
unlock the front panel, or turn
it 90° clockwise to lock the
front panel.
The screw does not turn 360°. So
avoid damage to the screw, do
not use excessive force when
turning it.
Unlock position mark
Lock position mark

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)