Title Function Adjustment range Default setting
H
Frequency free unit
magnification
0.00: Free unit display disabled (display of
frequency)
0.01-200.0
0.00
H
Inclination
characteristic of free
unit display
0: Negative inclination (downward slope)
1: Positive inclination (upward slope)
1
H
Bias of free unit
display
0.00-HJ 0.00
*TheHconverts the following parameter settings:
Free unit Frequency monitor display
Frequency-related parameters HJ,WN, NNUT, UT,
H, H, H, H,
H, H, H,
H, H, H, H,
H, H, H, H,
H, H-H, H-H,
H, H, H, H,
H, H
Q An example of setting when HJ is 80 and H is 10.00
H=1, H=0.00 H=1, H=20.00
0
800
Operation
panel display
080
Output frequency
(Hz)
200
1000
Operation
panel display
0
0
80 (Hz)
Output frequency
H=0, H=80.00
0
800
Operation
panel display
0 80 (Hz)