EasyManuals Logo

Toshiba TOSVERT VF-S11 User Manual

Toshiba TOSVERT VF-S11
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #69 background imageLoading...
Page #69 background image
E6581158
D-6
4
Q Example of parameter setting
Steps in setting are as follows
(Example of changing the dynamic braking selection H from 0 to 1.)
Key operated LED display Operation
.
Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])
CWJ
The first basic parameter “CWJ” (history function) is displayed.
H
Press either the or the to change to the parameter group
H.
H
Press the ENTER key to display the first extended parameter
H.
H
Press the key to change to the dynamic braking selection H.
Pressing the ENTER key allows the reading of parameter setting.
Press the key to change the dynamic braking selection from to
.
H
Pressing the ENTER key alternately flashes on and off the parameter
and changed value and allows the save of those values.
If there is anything you do not understand during this operation, press the MODE key several times to
start over from the step of CWJ display.
4.1.3 Search and resetting of changed parameters (I4Wҗ)
Automatically searches for only those parameters that are programmed with values different from the
standard default setting and displays them in the user parameter group I4W. Parameter setting can also be
changed within this group.
Notes on operation
If you reset a parameter to its factory default, the parameter will no longer appear in I4W.
Q How to search and reprogram parameters
The operations of search and resetting of parameters are as follows.
Key operated LED display Operation

Displays the operation frequency (operation stopped).
(When standard monitor display selection H= [Operation
frequency])
CWJ
The first basic parameter “CWJ” (history function) is displayed.
ITW Press or key to select I4W.
MODE
MODE

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)