[Parameter setting]
Title Function Adjustment range Default setting
CW
Automatic acceleration/deceleration
0: Disabled (manual)
1: Automatic
2: Automatic (only at acceleration)
0
, When automatically setting acceleration/deceleration time, always change the acceleration/deceleration
time so that it conforms with the load. The acceleration/deceleration time changes constantly with load
fluctuations. For inverters that requires a fixed acceleration/deceleration time, use the manual settings
(CEE, FGE).
, Setting acceleration/deceleration time (CEE,FGE) in conformance with mean load allows optimum set-
ting that conforms to further changes in load.
, Use this parameter after actually connecting the motor.
, When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or
deceleration time in time, and therefore may be tripped.
[Methods of setting automatic acceleration/deceleration]
Key operated LED display Operation

Displays the operation frequency.
(When standard monitor display selection H is set to [Op-
eration frequency])
CWJ
The first basic parameter “CWJ” (history function) is displayed.
CWK Press the key to change the parameter to CWK.
Pressing the ENTER key allows the reading of parameter setting.
Press the key to change the parameter to or .
CW
Press the ENTER key to save the changed parameter. CW and the
parameter are displayed alternately.
5.1.2 Manually setting acceleration/deceleration time
Set acceleration time from 0 (Hz) operation frequency to maximum frequency HJ and deceleration time as
the time when operation frequency goes from maximum frequency HJ to 0 (Hz).
Output frequency (Hz)
F
FF
FGE
GEGE
GEC
CC
CEE
EEEE
EE
H
HH
HJ
JJ
J
Time [sec]
O
CW = (Manual)
MODE

Table of Contents

Other manuals for Toshiba TOSVERT VF-S11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-S11 and is the answer not in the manual?

Toshiba TOSVERT VF-S11 Specifications

General IconGeneral
ModelTOSVERT VF-S11
CategoryInverter
Output Frequency0.1-400Hz
Frequency Range0.1-400Hz
Control MethodV/f Control, Sensorless Vector Control
Power Rating0.2kW to 15kW
Cooling MethodForced air cooling
Overload Capacity150% for 60 seconds
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
CommunicationModbus RTU
Input Voltage200-240V, 380-480V
Braking UnitBuilt-in (optional external braking resistor)

Related product manuals