TRACKMASTER Ch. 12 Removal and Replacement of Components
317-160-406 Rev 4 TMX428 TMX428CP & TMX58 Service Manual 125
May 2021
TMX428CP & TMX58 PARAMETER SCREEN
To gain access to the parameter screen hold down on QUICK SPEED for approximately 4
seconds.
Parameter screen description:
P02 Stop History
P05 Maximum Speed Setting
P09 Accurate Speed B (External Sensor)
P10 Firmware version (Lower Board)
P14 Accurate Speed A (Motor Controller)
P15-P20 Elevation Calibration Points
P22 Run Time
P30 Calibration Fail Code (0=Calibrated)
C00 Setting = 1 Quick Speed Enabled
Setting = 3 Quick Speed Disable
C01 Minimum Start Speed 0.0 to 1.0 MPH
C02 Maximum Elevation
SPD Manual Control Speed Any +or- Key
ELE Manual Control Elevation Any +or- Key
NOTE: Do not alter any parameter values with Consulting the factory. Altering the
parameters may cause the treadmill to malfunction.
TMX428CP & TMX58 STOP HISTORY
To view history highlight the P2 parameter and hold down on the QUICK SPEED 2 for
approximately 5 seconds.
Using the + or – key, this allows you to highlight a specific stop code and receive a breif
description for stopping (Example 34 is NORMAL STOP).
Start Rejected (8 or 40)
Stop due to kill switch open (16 or 48)
Motor Controller Fault (64 or 96)
Overspeed Motor Controller (128 or 160)
Overspeed External Speed Sensor (256 or 288)
Speed Delta Error (512 or 544)
Set Speed to Zero Command (1024 or 1056)
Auto Stop Command (2048 or 2080)
Measured Zero Speed Error (8224)
TMX428 VERSION 0.4C
ENTER: NEXT PROG: PREV +- EDIT START: EXIT
STOP HISTORY (00=MOST RECENT)
+- SELECT COOL DOWN:EXIT