8-Printer Commands Epic Edge™ OEM Integration Manual
100-14444 Rev B August 2018 Page 81
ESC BEL – Configure Audio Alert
Description
The ESC BEL command alters the way the audio alert sounds when the BEL command
is issued. The default is a single sound lasting the period of time defined by the audio
alert setting parameters below.
See also:
BEL – Audio Alert
Expression
ASCII
[ESC] [BEL] <n1> <n2> <n3>
Hexadecimal
1BH 07H <
n1
> <
n2
> <
n3
>
Decimal
<27> <7> <
n1
> <
n2
> <
n3
>
Parameters <n1> is the number of alert cycles
<n2> is the on time of the alert cycle in ten Ms intervals
<
n3
>
is the off time of the alert cycle in ten Ms intervals