15.Waveform Reading
99
15-8. Control Signal Display
The input conditions of the H/M and T/H signals are displayed together with the graph
on the screen.
Setting item: ON / OFF
Display is provided when the Control Signal Display setting is "ON".
MODE Read Wave Control Signal
T/H (pink)
H/M (green)
In modes other than the Hysteresis / Hysteresis 2 mode
Go
Return
In the Hysteresis / Hysteresis 2 mode
(The colors and up-and-down relationship between the H/M and
T/H signals are the same as the above.)