23.Specifications
159
23-8. General Performance
Power supply voltage: AC100 ~ 240V (+10%, -15%) 50/60Hz
Power consumption: 25W(50VA) MAX (at 240V steady-state)
Rush current (Typ): 20A 5msec :100V AC max. load condition
(ordinary temperature, at cold-start)
40A 5msec :200V AC max. load condition
(ordinary temperature, at cold-start)
Operating conditions: Temperature:
Operating temperature range:
0 ~ +40 (non-condensing)
Storage temperature range:
-20 ~ +60 (non-condensing)
Humidity: 85%RH or less (non-condensing)
Outer dimensions: 174W × 156D × 135H [mm]
* Not including projections.
Panel cut dimensions: 165W ( ) × 130H ( ) [mm]
Panel thickness: 1.6 3.0 [mm]
Weight: Approx. 2.3 [kg]
23-9. Option
Pulse input option
PUI Pulse input
Serial comunication interface option
ODN DeviceNet interface
CCL CC-Link interface
(Up to 3 options and 1 serial communication interface option are available.)