24.Setting Items list
161
24. Setting Items list
Mode Setting item Initial value NOV.
RAM
SRAM LOCK
(SW)
LOCK
(
SOFT
)
Input digits or selections
CH1 CAL. EXC. Volt 2.5V
◎◎○
0: 2.5V 1: 10V
Zero CAL
◎◎○
Execution screen
Equiv. CAL. (input value) 2.000
◎◎○
4 digits (The explanatory display is changed
according to the mounting condition.)
Equiv. CAL (load) 500.0
◎◎○
4 digits
Actual CAL. 500.0
◎◎○
4 digits (The explanatory display is changed
according to the mounting condition.)
Digital Flt. None
◎◎
0: None 1: 2 2: 4 3: 8 4: 16 5: 32
Analog Flt. 600Hz
◎◎
0: 10Hz 1: 50Hz 2: 200Hz 3: 600Hz
Decimal Place xxx.x
◎◎○
0: x, 1: x.x 2: x.xx 3: x.xxx
Unit kN
◎◎○
Digital Offset 0.0
◎◎◎
4 digits + sign
Increment 0.1
◎◎◎
3 digits
CH2 CAL. Axis Status display
EXC. Volt 2.5V
◎◎○
0: 2.5V 1: 10V (The setting cannot be made
depending on the mounting condition.)
Zero CAL.
◎◎○
Execution screen
Equiv.CAL. (input value) 5.000
◎◎○
4 digits (The explanatory display is changed
according to the mounting condition.)
Equiv.CAL. (magnitude) 500.0
◎◎○
4 digits (The explanatory display is changed
according to the mounting condition.)
Actual CAL. 500.0
◎◎○
4 digits (The explanatory display is changed
according to the mounting condition.)
Digital Flt. None
◎◎
0: None 1: 2 2: 4 3: 8 4: 16 5: 32
Analog Flt. 600Hz
◎◎
0: 10Hz 1: 50Hz 2 :200Hz 3: 600Hz
Decimal Place xxx.x
◎◎○
0: x, 1: x.x 2: x.xx 3: x.xxx
Unit kN
◎◎○
Digital Offset 0.0
◎◎◎
4 digits + sign (only plus at X-axis setting)
Increment kN
◎◎◎
3 digits
Operation Mode Operation Mode Multi-hold
◎◎
0: Multi-hold 1: Wave Comp 2: Hysteresis
3: Wave & Displace 4: Hysteresis 2
Sample Rate 1kHz
◎◎
0: 4k 1: 2k 2: 1k 3: 500 4: 200 5: 100
Code Set
[0-31] ch
Ch. No. 0
◎
2 digits. 0 will result when the power is turned on.
Parameter Copy 0
◎◎
2 digits
Select CH CH1
◎◎
0: CH1 1: CH2
Hold Set None
◎◎
See 16-2-4.
HI Limit +100.0
◎◎
4 digits + sign
HI-HI Limit +999.9
◎◎
4 digits + sign
LO Limit +1.0
◎◎
4 digits + sign
LO-LO Limit -999.9
◎◎
4 digits + sign
DPM Hi 999.9
◎◎
4 digits
DPM LO 0.0
◎◎
4 digits
Wave Start Level +1.0
◎◎
4 digits + sign
Wave End Level +0.0
◎◎
4 digits + sign
Hold Timer 1000
◎◎
4 digits
P&V Difference 1.0
◎◎
4 digits
P&V Judg. Rate 25%
◎◎
0: 25% 1: 50% 2: 75% 3: 125% 4: 150% 5: 200%
6 :300% 7: 400%
P&V Ordinal 1
◎◎
1 digits
Minimum Slope 1.0
◎◎
4 digits
Interval A 20
◎◎
3 digits
Interval B 20
◎◎
3 digits
Pre-Point 0
◎◎
2 digits
Inhibit Timer 0
◎◎
4 digits
Hys. Interval 1.0
◎◎
4 digits
F-T Limit 4000
◎◎
4 digits
F-T Output ON
◎◎
0: ON 1: OFF
HH/LL Mode Hold
◎◎
0: Hold 1: Sample
Lv. Axis Select Y Axis
◎◎
0: Y Axis 1: X Axis
Hold Start Level
-9999(Invalidity)
◎◎
4 digits + sign
Auto Code Up OFF
◎◎
0: ON 1: OFF
Code Up Point 0
◎◎
4 digits
HI-LO Relative OFF
◎◎
0: ON 1: OFF
DPM HI-LO Mode Peak value
◎◎
0: Hold Value 1: Peak Value 2: Both
DPM Hold HI 9999
◎◎
4 digits
DPM Hold LO 0
◎◎
4 digits
U. Area Output ON
◎◎
0: ON 1: OFF
0:kg 1:t 2:g 3:N 4:kN
5:MN 6:N•m 7:Pa 8:kPa 9:MPa
10:bar 11:N/m
2
12:mm 13:cm 14:μm
15:rad 16:deg 17:lb 18:oz 19:dyne
20:psig 21:ftlb 22:inlb 23:inoz 24:ft
25:in 26:None
0:kg 1:t 2:g 3:N 4:kN
5:MN 6:N•m 7:Pa 8:kPa 9:MPa
10:bar 11:N/m
2
12:mm 13:cm 14:μm
15:rad 16:deg 17:lb 18:oz 19:dyne
20:psig 21:ftlb 22:inlb 23:inoz 24:ft
25:in 26:None