10.Multi-Hold Mode
50
10-3-2. Peak Hold
The maximum value (peak value) in the positive direction is held.
t1: Delay time between the instant when the T/H signal is input and the instant when the
indicated value is held.
Ts+0.8msec (max.)
t2: Delay time between the instant when the T/H signal is cancelled and the instant when
the indicated value returns to tracking.
Ts+0.8msec (max.)