70
6 Useful Functions
70
Useful Functions
Chapter
6
- Read accumulated data
- Read setting value [Example: final]
- Writing setting values [Example: final]
- Command [Example: tare subtraction]
- Zero calibration
- Span calibration
Host
F701+
Weighed value
Host
F701+
Return data with no accumulated data in the buffer.
* Up to 256 data can be saved in the memory buffer,
and the data are deleted starting from the oldest when they are read.
R CRJ
R
CRLF
J + 1 0 0 0 0. 0
R CR
J
R
CR LF
J
Host
F701+
W
W CR
CR
Setting value No.
5-digit setting value (no decimal point)
LF
Setting value No.
1 2
1 2 1 0 0 0 0
Host
F701+
W CR
Setting value No.
5-digit setting value
LF
* No return data
(no decimal point)
1 2 1 0 0 0 0
Host
F701+
C CRE
* No return data
Host
F701+
C CR
0
0 0 0 CR
0
LF
A
0N A 0
Calibrating
0: Normal end, 2 to 9: Error
(same as error display no. of main unit)
Host
F701+
C CR
0
0 0 0 CR
0
LF
B
0N B 0
Calibrating
0: Normal end, 2 to 9: Error
(same as error display no. of main unit)
* Set capacity, min. scale division, balance weight, etc. before sending this command.