46
5 Timing Chart for Weighing
46
Timing Chart for Weighing
Chapter
5
5-2. Normal sequence control
Near zero
Final - Set point 1
Final - Set point 2
Final - Compensation
Final
NET
Time
Tare subtraction
input
Start
input
SP1
output
SP2
output
SP3
output
Comparison inhibit timer
Judging timer
Complete timer
Judging
output
Over, go or under
t0 t1
t2
t3
Hold
Restart
input
Over
Under
No.2
No.1
No.3
No.4
No.6
No.5 No.7
No.9
No.10 No.11
t3
No.12
No.8
*1
*2
*3
*4
*5
t0: comparison inhibit time 1
t1: comparison inhibit time 2
t2: judging time
t3: complete output time
SP1: set point 1
SP2: set point 2