EasyManua.ls Logo

Unipulse F701+ - Sequence Control (with External Judging)

Unipulse F701+
149 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
5 Timing Chart for Weighing
50
Timing Chart for Weighing
Chapter
5
5-4. Sequence control (with external judging)
Near zero
Final - Set point 1
Final - Set point 2
Final
NET
Time
Judging
input
Judging timer
Complete
output
Judging
output
Go
t2
t3
Hold
t2
Waiting for
external judging
output
Comparison inhibit timer
t0 t1
Flashes
Status display
Final - Compensation
Over
Under
t1
Tare subtraction
Start
input
SP1
output
SP2
output
SP3
output
No.2
No.1
No.3
No.4
No.6
No.5 No.7
No.9
No.10
No.12
No.11
No.14
No.8
No.13
*1
*2
*3
*6
*4
*5
*7
*4
Over, go or under
input
t0: comparison inhibit time 1
t1: comparison inhibit time 2
t2: judging time
t3: complete output time
SP1: set point 1
SP2: set point 2
SP3: set point 3

Table of Contents

Related product manuals