5.4 Tool I/O
CAUTION:
1. Never use the “on” input or the power button to turn off the
control box.
5.3.7.1 Remote ON button
The illustration below shows how to connect a remote on button.
5.3.7.2 Remote OFF button
The illustration below shows how to connect a remote off button.
5.4 Tool I/O
At the tool end of the robot there is a small connector with eight pins, see illustration
below.
This connector provides power and control signals for grippers and sensors used
on a specific robot tool. The following industrial cables are suitable:
• Lumberg RKMV 8-354.
The eight wires inside the cable have different colors. The different colors designate
different functions, see table below:
Color Signal
Red 0V (GND)
Gray 0V/+12V/+24V (POWER)
Blue Tool output 0 (TO0)
Pink Tool output 1 (TO1)
Yellow Tool input 0 (TI0)
Green Tool input 1 (TI1)
White Analog input 2 (AI2)
Brown Analog input 3 (AI3)
UR5/CB3 I-38 Version 3.4.5