EasyManuals Logo

Vacon NX series Applications Manual

Vacon NX series
392 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Table 20: Motor control parameters, G2.6
Index Parameter Min Max Unit Default Cust ID Description
P2.6.14.11 Start-up torque 0 3 0 621
0 = Not used
1 = Torque mem-
ory
2 = Torque refer-
ence
3 = Start-up torque
fwd/rev
P2.6.14.12
Start-up torque
FWD
-300.0 300.0 % 0.0 633
P2.6.14.13
Start-up torque
REV
-300.0 300.0 % 0.0 634
P2.6.14.15
Encoder filter
time
0.0 100.0 ms 0.0 618
P2.6.14.17
Current control P
gain
0.00 100.00 % 40.00 617
Identification parameter group 2.6.15
P2.6.15.1 Speed step -50.0 50.0 0.0 0.0 1252
NCDrive speed
tuning
* = Parameter value can only be changed after the AC drive has been stopped.
VACON · 64 LOCAL/REMOTE CONTROL APPLICATION
3
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205

Table of Contents

Other manuals for Vacon NX series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX series and is the answer not in the manual?

Vacon NX series Specifications

General IconGeneral
Product typeAC Drive
Output voltage range0-Uin
Frequency range0-500 Hz
Enclosure classesIP00, IP21
Mounting typesWall
Braking chopperIntegrated or external
EMC filterBuilt-in or external
Control modesScalar, Vector
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Communication optionsModbus, Profibus, CANopen, Ethernet
Ambient temperature range-10°C to +50°C
Cooling methodAir-cooled

Related product manuals