2-8 SHB 803 en – Edition 2.4 * 803s210.fm
Technical data
2.7 Noise levels
Measurements performed on asphalted surface.
2.8 Vibration
Vibration values indicated in m/s².
2.9 Coolant compound table
Use the 1:1 concentration for warm outside temperatures, too:
Protection against corrosion, cavitation and deposits
Do not mix the coolant with other coolants.
Machine filled at the factory with Eurolub SF D12 coolant (ethylene glycol basis).
Sound power level Model 803
Sound power level (L
WA
)
1
1. ISO 6395 (EC Directives 2000/14/EC and 2005/88/EC)
93 dB (A)
Operator-perceived sound pressure level (L
PA
)
2
2. EN ISO 4871 (EC Directives 2000/14/EC and 2005/88/EC)
77 dB (A)
Uncertainty (K
PA
)
3
3. ISO 6394 (EC Directives 84/532/EEC, 89/514/EEC, 95/27/EEC)
1.2 dB (A)
Vibration
Effective acceleration value for the upper extremities of the
body (hand-arm vibration)
< Trigger value
< 2.5 m/s
2
Effective acceleration value for the body (whole-body vibration) < 0.5 m/s
2
Outside temperature
Coolant
Water Anticorrosion agent Antifreeze agent
Up to °C (°F)
% by
volume
cm³/l / (in
3
/gal) % by volume % by volume
-37 (-34.6) 50 10 (2.6) 1 50