Wacker Neuson 803 - Checking the Coolant Level;Adding Coolant

Wacker Neuson 803
196 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SHB 803 en – Edition 2.4 * 803s312.fm 3-23
Maintenance
Checking the coolant level/adding coolant
Danger!
Never open the coolant reservoir and never drain coolant
if the engine is warm since the cooling system is under high pressure.
Burn hazard!
☞Wait at least 15 minutes after stopping the engine!
☞Wear protective gloves and clothing
☞Open filler cap B to the first notch and release the pressure
☞Ensure that the coolant temperature is sufficiently low so you can touch the
radiator plug with your hands
Danger!
Coolant is flammable and poisonous.
Accident hazard!
☞Keep away from flames
☞Avoid eye contact with coolant
• If coolant comes into contact with the eyes
➥Immediately rinse with clean water and seek medical assistance
Notice!
Do not add a different coolant to the one in the reservoir.
• Only use the coolant prescribed by Wacker Neuson
– see Fluids and lubricants on page 3-2.
Checking the coolant level
☞Park the machine on level ground
☞Stop the engine!
☞Raise the control lever base
☞Remove the key and carry it with you
☞Let the engine and the coolant cool down
☞Open the engine cover
☞Check the coolant level on the transparent coolant reservoir 13/A and on radiator 12/B
☞If the coolant level is below the lower mark or if there is no coolant at the radiator’s
filler inlet:
➥Add coolant
☞Close and lock the engine cover
Fig. 12: Radiator cap
B
A
max.
min.
Fig. 13: Coolant reservoir