WAGO I/O System Compact Appendix 141
751-9301 Compact Controller 100
Manual
Version 1.1.0, valid from FW Version 03.08.07(20)
15.1.1.2.4 “Configuration of Host and Domain Name” Page
The settings for the hostname and domain are displayed on the “Configuration of
Host/Domain Name” page.
“Hostname” Group
Table 71: WBM “Configuration of Host and Domain Name” Page “Hostname” Group
Parameter
Explanation
Currently used
If you have selected dynamic assignment of an IP
address via DHCP, the name of the host currently
being used is displayed.
Configured
Enter the product hostname here; it is then used if
the network interface is changed to a static IP
address or if no hostname is assigned per DHCP
response.
Click the [Submit] button to apply a change.
Click the [Clear] button to reset the input field.
The change takes effect immediately.
If a hostname is supplied via a DHCP response, this is enabled in the system. If
there are several network interfaces with DHCP, the last received hostname is
always valid.
If only the hostname configured here is to be valid, the configuration of the DHCP
server must be adapted so that no hostnames are transferred in the DHCP
response.
“Domain Name” Group
Table 72: WBM “Configuration of Host and Domain Name” Page “Domain Name” Group
Parameter
Explanation
Currently used
If you have selected dynamic assignment of an IP
address via DHCP, the name of the domain
currently being used is displayed.
Configured
Enter the product domain name here; it is then used
if the network interface is changed to a static IP
address or if no domain name is assigned per
DHCP response.
Click the [Submit] button to apply a change.
Click the [Clear] button to reset the input field.
The change takes effect immediately.
If a domain name is supplied via a DHCP response, this is enabled in the system.
If there are several server network interfaces with DHCP, the last received
domain name is always valid.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGO Compact Controller 100 and is the answer not in the manual?

WAGO Compact Controller 100 Specifications

General IconGeneral
BrandWAGO
ModelCompact Controller 100
CategoryI/O Systems
LanguageEnglish

Related product manuals