Applicator Setup
Weber Packaging Solutions, Inc. 4-11
Air Blast Adjustment
The Air Blast Regulator is factory-set to give the best label application performance for a wide variety
of label sizes. Adjustments may be made to the air blast timer and air blast regulator.
Refer to Chapter 6 to see how to access and set the air blast time menu on the controller.
To adjust the air blast:
1. Position the applicator to apply a label to a product. The tamp, when fully extended,
should stop ¼” away from the product to be labeled.
2. Set the main [POWER ON/OFF] switch to the ON position. Wait for the applicator and
print engine to fully power up.
3. Place a stationary product below the tamp and press the [FEED] button to dispense a
label on the tamp pad, then trip the product detector to cycle the tamp and transfer the
label to the product.
4. Observe the transfer of the label. Make sure the air blast duration is long enough to
allow the air jets to transfer the label.
5. Some experimentation will be necessary to find the best time to use.