B95W
Maintenance
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
201 / 306
6
20
6.8 Decommissioning
6.8.1 Preservation measures for taking the machine out of service
temporarily
Preservation
measures to
protect the
machine
We recommend keeping the machine in a dry, dust-free room during the
storage period.
Thoroughly clean the inside and outside of the machine, including the engine.
Lubricate the machine in accordance with the lubrication schedule.
J See chapter 6.5.1 “Lubrication schedule”.
Check and top up all oil levels in components such as the engine, transmission,
etc.
Check and top up the hydraulic oil level.
Repair paint damage.
Fill the diesel fuel tank completely to avoid wall corrosion.
Fill the AdBlue
®
tank to the top.
a)
To avoid disintegration, the transport and storage temperatures should not
exceed 25 °C for any longer period of time.
b)
Significant reduction of shelf life: inspect each lot before use.
The main factors that influence shelflife are the constant storage temperature
and the alkalinity of the AdBlue
®
solution. Varying evaporation levels of
ventilated and unventilated storage containers further affects shelflife.
Dangers posed by long periods of non-usage
Machine damage caused by bearing defects (e.g., corrosion
damage) if the equipment is not used for more than three
months.
Z Take preservation measures.
Max. constant storage temperature
(°C)
Min. shelf-life (month)
≤ 10 36
≤ 25
a)
18
≤ 30 12
≤ 35 6
> 35 --
b)