B95W
Maintenance
166 / 306
6
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
20
6.7.8 Hydraulic oil tank
Check hydraulic
oil level
Danger posed by hot oil and machine parts, and a
pressurized hydraulic system
Risk of burns. Risk of serious injury – hydraulic oil can get
under the skin.
Z Depressurize the hydraulic system for any maintenance or
servicing. With the engine turned off, lower the loading
equipment to the ground and actuate all hydraulic operating
levers until there is no more pressure in the hydraulic
system.
Z Avoid skin contact with oil, grease, and machine parts.
Z Wear personal protective equipment.
Z In the event of injuries, seek medical attention.
Notice
• Park the machine in a horizontal position.
• Place the loading equipment flat on the ground.
• Completely retract the bucket cylinder and the dipperstick cylinder
and completely lower the boom, articulated to the left, onto the
ground.
• Place the dozer blade on the ground.
Notice
Fold down/fold up maintenance ladder. See chapter 6.7.5 “Fuel system”.