Check the antifreeze properties of the coolant and adapt these, if necessary.
Apply all preservation measures as specified in the operating instructions for
the engine.
Protect tires from direct sunlight.
Treat bare piston rods with a commercially available corrosion protection agent.
Remove the battery, clean it, and store it properly in a dry and, over winter,
in a frost-free room. Cover the poles with pole grease.
Close the air intake openings of the air filter system and the exhaust outlet on
the exhaust pipe.
Switch off the battery isolator switch.
6.8.2 While out of service
Movements
The anti-corrosion coat must be cleaned from the piston rods, and the openings
of the air filter system and the exhaust pipe freed.
Once the machine has been out of use for six months, all assemblies must be
brought to operating temperature and set in motion for approx. 15 minutes.
Renew the preservation measures after performing these movements.
6.8.3 At the end of the period of non-usage
Before recommissioning the machine, the following measures must be carried out:
Putting the machine back into service
Clean the piston rods to remove the corrosion protection coating.
Clear the air intake of the air filter and the exhaust opening.
Check the condition of main air filter cartridge and safety cartridge, replace if
necessary.
Wash the machine with a neutral detergent.
Check the battery, recharge if necessary and install it.
Carry out all measures for putting the diesel engine back into service as
detailed in the engine operating instructions.
If the machine has been out of use for more than 6 months, the oil in
assemblies such as the engine, transmission, etc. must be changed.
As soon as the machine has been out of action for six months (if not before),
replace the hydraulic filters (pressure, return, and ventilation filter, if applicable).
Lubricate the machine in accordance with the lubrication schedule.