B95W
Maintenance
132 / 306
6
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
20
6.7 Maintenance and inspection tasks
6.7.1 Display
Checking the fluid levels
Switch on the ignition
J The “hydraulic oil level” symbol on the display flashes red when the minimum
level is reached.
J The coolant level” symbol on the display flashes yellow when the minimum
level is reached.
If required, top up the missing fluid.
WARNING
Danger posed by dislodged parts
Air cleaning with compressed air can dislodge parts and
result in eye injuries.
Z Wear personal protective equipment.
CAUTION
Environmentally hazardous substances
Environmental damage caused by environmentally
hazardous substances.
Z Do not allow waste oil to seep into the ground.
Z Always place a receptacle for the collection of waste oil
under the working area (when draining oil or removing the
filter element).
Z Collect the waste oil and dispose of it according to
regulations!
Notice
All maintenance and inspection work must be performed acc. to the
inspection plan.
See chapter 6.6 “Checking, maintenance and inspection plan”.
Notice
All checks must be carried out with the machine standing on level
ground and cooled down.