EasyManua.ls Logo

Yanmar B95W - Page 133

Yanmar B95W
310 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B95W
Maintenance
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
131 / 306
6
20
Tab. 6-8 Machine inspection plan
48 Test run and test work o o --
49 Sign inspection card and return to
manufacturer
oo
5)
115
1)
Diesel engine: Depending on individual cases, the lubricating oil consumption may be too high. In
this case and when the constant ambient temperature is below -10 °C or if the lubricant temperature
is below 60 °C, the lubricant change interval should be halved.
2)
Diesel engine: Lubricating oil change interval specification, related to lubricating oil quality DQC III.
3)
Diesel engine: Complete overhaul after approx. 5000 operating hours. The optimal time for a
complete overall is highly influenced by use, operating conditions of the environment and the care
and maintenance the engine has received during its use. Your DEUTZ representative will advise you
on when the best time for a complete overhaul might be.
4)
Extension of oil change intervals after an oil analysis and laboratory report.
See chapter 6.3.1 “Regular oil analyses”.
5)
Under warranty.
6)
At least every two years.
No. Inspection Hours in operation
Page
o = Check, maintenance
x = Replace
After
100
every
500
every
1000
every
3000
at least
2 x year
at least
1 x year

Table of Contents

Related product manuals