10.3 Troubleshooting and fault rectification
10.3.1 General malfunctions
Fault Machine fails to drive
Cause Left-hand armrest control panel lifted or switch defective
Pilot pressure too low or no pilot pressure at all
Low hydraulic oil level
Hydraulic pump has failed
Corrective
measure
Lower armrest panel.
Check pilot pressure
Top up the hydraulic oil to the mark
Have pump checked by specialist and replace if necessary
Fault Poor travel performance
Cause Engine output is insufficient
Pump has insufficient output
Corrective
measure
Check diesel engine
Check the pump and replace if necessary
Fault Excavator equipment not working
Cause Toggle switch for working hydraulics set to “OFF”
Left-hand armrest control panel lifted or switch defective
Switch on armrest panel defective
Oil supply to hydraulic pump interrupted
Hydraulic pump has failed
Main relief valves have failed
Maintenance cover folded down
Switch on maintenance cover defective
Corrective
measure
Switch the working hydraulics toggle switch
Lower armrest panel
Check the switch and repair or replace if necessary
Check lines
Have hydraulic pump checked by a specialist and replace, if necessary
Check main relief valves and replace, if necessary
Close maintenance cover
Repair or replace maintenance cover switch