30
Fault Insufficient performance of service brake
Cause Wear in brake discs
Brake system damaged
Corrective
measure
Repair brake discs
Repair or replace brake system
Fault Parking brake without function
Cause Spring-loaded brake mechanically unblocked
Hydraulic fault in spring-loaded brake actuation
Corrective
measure
Activate spring-loaded brake
Repair spring-loaded brake
Fault Malfunctions in the electrical system
Cause Outside and/or interior lighting does not come on
Windshield wiper is not working
Starting system not working satisfactorily
Horn not responding
Indicator elements are imprecise
Corrective
measure
Check cables, connections, bulbs, and fuses for lighting
Check cables, connections, and fuses for windshield wipers
Examine windshield wiper for mechanical damage; replace if necessary
Check charge capacity of battery. Test starter function. Check connection
and condition of power and ground cables. Check function of ignition lock and
starting relays; replace if necessary
Check cables, connections, and fuses for signal horn; replace signal horn if
necessary
Determine the fault or source of the indicator element problem and eliminate
it, call service personnel if necessary
Fault Faults in the overload warning device
Cause No visual indication
No acoustic warning
Overload warning sensor or indicator module defective
Overload warning device is not switched on
Corrective
measure
Call Service agent to check overload warning sensor or display module
Switch on overload warning